AWGearMeters8809IndustrialDrive,Franksville,WI53126web:www.awgearmeters.com
Tel:2628849800Fax:2628849810Email:awinfo@awlake.com
REV.10/01CAPM2N.DOC
CAPM-2N Carrier Frequency Pickup Module
Description:
The CAPM-2N is used with the HPM series and the TR series of flow meters. The CAPM-2N is a
Carrier Frequency sensor which means there is no permanent magnet in the pickup and any
magnetic drag on the flow meter gears or turbine is avoided. The CAPM-2N requires a supply voltage
between 10 Volt DC to 30 Volt DC. A diode in the supply input prevents damage to the module in
case the polarity of the supply voltage is wrong. The output signal is a square wave. The frequency is
proportional to the flow rate.
The output is a sinking open collector NPT transistor.
Technical Data :
Supply Voltage : 10 to 30 Volt DC
Supply Current : 9 mA @ 15 Volt, Max 18mA
Minimum Signal : 0.5 Hz
Duty Cycle : 50%
Frequency Output : Flow dependent, up to 2000 Hz
Sinking Capacity: 50 mA Max
Temperature Range: -60F to 185F (-50C to 85C)
Connections:
A - +10 to 30 Volt DC supply voltage
B - Ground for supply and signals
C - Frequency signal output
AW Company wire color code:
Supply Voltage: Red
Ground: Black
Signal: White